Página 1 - Emergency Relief Valve

IOM2000A.4 Rev. A 12541 © 2008 Groth Corporation Installation, Operation and Maintenance Manual for Emergency Rel

Página 2 - TABLE OF CONTENTS:

10 Figure 10: Sealant tape on Vacuum Seat 5. Apply PTFE sealant tape around the inside hole pattern of the vacuum seat [18] (Figure 10). Tape shou

Página 3

11 16. Place spring [31] over the stem [14]. Use the spring button [16] to compress the spring [31]. Insert nuts [15] and tighten. Compress the sp

Página 4 - SAFETY WARNINGS

12 MODEL 2400A DISASSEMBLY & ASSEMBLY ITEM DESCRIPTION ITEM DESCRIPTION 1 Body 10 Diaphragm 2 Pallet 11 Washer, 3/8", PT

Página 5 - INSPECTION AND INSTALLATION

13 MODEL 2450A DISASSEMBLY & ASSEMBLY ITEM DESCRIPTION ITEM DESCRIPTION 1 Body 17 Stem Guide 2 Pallet – Pressure 18 Seat – Vacuum 3

Página 6 - PREVENTIVE MAINTENANCE

14 second nut from the stem. Slowly raise the spring button to release the spring compression. The spring force will be in 5 – 30 lb range, dependi

Página 7

15 Figure 17 : Sealant tape on Vacuum Seat 4. Place retainer plate [3], align with pallet hole pattern. 5. Apply PTFE sealant tape around the ins

Página 8

16 16. If pallet assembly is high enough from the table, insert vacuum pallet-stem [23, 24, 14] assembly from beneath. Place a short length of pipe

Página 9

17 TESTING AND SETTING PROCEDURE SETUP After final assembly, mount the valve on a tank vent test stand or on a blind flange with instrument tap. Use

Página 10

19 MODEL INFORMATION The nameplate on the Groth Series 2000A Emergency Relief Valves contains the model number, serial number, set pressure and flow

Página 11

2 TABLE OF CONTENTS: INTRODUCTION: 2 DESIGN, FUNCTION & OPERATION 3 GENERAL SAFETY INSTRUCTIONS 4 SAFETY WARNINGS 4 INSPECTION AND INSTALLA

Página 12

3 DESIGN, FUNCTION & OPERATION The 2000A Series was designed as a cost effective valve that would protect a tank by providing emergency pressur

Página 13 - Hex Bolt, 3/8-16 UNC

4 GENERAL SAFETY INSTRUCTIONS This section is an overview of safety guidelines that should be followed during the installation, operation and mainten

Página 14

5 INSPECTION AND INSTALLATION The ERV is packed and supported to prevent damage or contamination during shipping. It should be similarly protected d

Página 15 - FluoropolymerWasher

6 PREVENTIVE MAINTENANCE The 2000A Series valves do not require routine lubrication or adjustments, but should be checked periodically, at least twic

Página 16

7 MODEL 2000A DISASSEMBLY & ASSEMBLY ITEM DESCRIPTION ITEM DESCRIPTION 1 Body 7 Hex Nut, 3/4"-10 UNC 2 Pallet 8 Washer, 3/4", PTF

Página 17

8 MODEL 2050A DISASSEMBLY & ASSEMBLY ITEM DESCRIPTION ITEM DESCRIPTION 1 Body 17 Stem Guide 2 Pallet – Pressure 18 Seat – Vacuum 3 R

Página 18 - MODEL INFORMATION

9 nut from the stem. Slowly raise the spring button to release the spring compression. The spring force will be in 5 – 30 lb range, depending on va